Volume 70 Issue 10
May. 2021
Turn off MathJax
Article Contents
Yang Jun, Wu Hao, Luo Kun-Hao, Guo Jin-Chuan, Zong Fang-Ke. Suppression of artifacts in X-ray phase-contrast images retrieved by Fourier transform[J]. JOURNAL OF MECHANICAL ENGINEERING, 2021, 70(10): 104101. doi: 10.7498/aps.70.20201781
Citation: Yang Jun, Wu Hao, Luo Kun-Hao, Guo Jin-Chuan, Zong Fang-Ke. Suppression of artifacts in X-ray phase-contrast images retrieved by Fourier transform[J]. JOURNAL OF MECHANICAL ENGINEERING, 2021, 70(10): 104101. doi: 10.7498/aps.70.20201781

Suppression of artifacts in X-ray phase-contrast images retrieved by Fourier transform

doi: 10.7498/aps.70.20201781
More Information
  • Corresponding author: Guo Jin-Chuan, Email: jcguo@szu.edu.cn; Zong Fang-Ke, E-mail: zongfk168@163.com
  • Received Date: 27 Oct 2020
  • Rev Recd Date: 11 Dec 2020
  • Available Online: 27 May 2021
  • Publish Date: 27 May 2021
  • Over the last two decades, the grating-based phase-contrast imaging has aroused the interest of a number of researchers. It could provide an access to three complementary signals simultaneously: the conventional absorption contrast, the differential phase contrast related to refraction of incident wave, and the dark-field contrast that relates to ultra small angle scattering in a sample. The grating-based phase-contrast signals have higher contrast sensitivity for some types of soft samples than the absorption signals. Dark-field signals have better diagnostic effects in the detection of lung tumors, pneumothorax and the identification of microcalcifications in breast. There are two main phase retrieval methods in grating-based X-ray phase-contrast imaging, i.e. phase stepping method and Fourier transform method. The phase signals retrieved by phase stepping is high precise and has low noise. But the sample suffers high dose due to at least three exposures. The phase signals retrieved by Fourier transform is low-dose due to the fact that only one image with sample is needed, but it is easily affected by artifacts when the size of the filtering window is too large. However, when the size of the filtering window is too small, the high-frequency information of the phase-contrast image will be lost, and the image will become blurred. A trade-off between definitions of the image and artifacts should be made. Since the phase-contrast signal and the dark-field signal of the sample are modulated by carrier fringes, the frequency spectrum of the detected image consists of many different harmonics. The artifacts in the retrieved signals originate from the spectrum aliasing between primary peak around zero spatial frequency and first-order harmonic peaks. Therefore, the subtraction between two images with phase difference can remove the primary peak, and the artifacts in the phase-contrast signals and dark-field signals will be suppressed. In order to further suppress the artifacts, we increase the frequency of carrier fringes, which results in a larger distance between first-order harmonic peaks in frequency domain. We finally attain artifact-free phase-contrast images and dark-field images while maintaining high definition of the images. The method proposed here is not only applicable to incoherent imaging system, but also to Talbot-Lau interferometer, and it would be useful in fast and low-dose X-ray phase-contrast and dark-field imaging.

     

  • loading
  • [1]
    David C, Nohammer E, Solak H H, Ziegler E 2002 Appl. Phys. Lett. 81 3287 doi: 10.1063/1.1516611
    [2]
    Momose A, Kawamoto S, Koyama I, Hamaishi Y, Takai K, Suzuki Y 2003 Jpn. J. Appl. Phys. 42 L866 doi: 10.1143/JJAP.42.L866
    [3]
    Pfeiffer F, Weitkamp T, Bunk O, David C 2006 Nat. Phys. 2 258 doi: 10.1038/nphys265
    [4]
    Pfeiffer F, Bech M, Bunk O, Kraft P, Eikenberry E F, Bronnimann C, Grunzweig C, David C 2008 Nat. Mater. 7 134 doi: 10.1038/nmat2096
    [5]
    Bech M, Tapfer A, Pauwels B, Bruyndonckx P, Sasov A, Pfeiffer F 2013 Sci. Rep. 3 3209 doi: 10.1038/srep03209
    [6]
    Anton G, Michel T, Pelzer G, Radicke M, Rieger J, Weber T 2013 Z. Med. Phys. 23 228 doi: 10.1016/j.zemedi.2013.01.001
    [7]
    Yang J, Guo J C, Lei Y H, Yi M H, Chen L 2017 Chin. Phys. B 26 028701 doi: 10.1088/1674-1056/26/2/028701
    [8]
    Weitkamp T, Diaz A, David C, Pfeiffer F, Stampanoni M, Cloetens P, Ziegler E 2005 Opt. Express 13 6296 doi: 10.1364/OPEX.13.006296
    [9]
    Takeda M, Ina H, Kobayashi S 1982 J. Opt. Soc. Am. 72 156 doi: 10.1364/JOSA.72.000156
    [10]
    Wen H, Bennett E E, Hegedus M M, Carroll S C 2008 IEEE Trans. Med. Imaging 27 997 doi: 10.1109/TMI.2007.912393
    [11]
    Wen H, Bennett E E, Hegedus M M, Rapacchi S 2009 Radiology 251 910 doi: 10.1148/radiol.2521081903
    [12]
    Lim H, Park Y, Cho H, Je U, Hong D, Park C, Woo T, Lee M, Kim J, Chung N, Kim J, Kim J 2015 Opt. Commun. 348 85 doi: 10.1016/j.optcom.2015.03.028
    [13]
    Lim H W, Lee H W, Cho H S, Je U K, Park C K, Kim K S, Kim G A, Park S Y, Lee D Y, Park Y O, Woo T H, Lee S H, Chung W H, Kim J W, Kim J G 2017 Nucl. Instrum. Methods Phys. Res., Sect. A 850 89 doi: 10.1016/j.nima.2017.01.022
    [14]
    Lim H, Lee H, Cho H, Seo C, Je U, Park C, Kim K, Kim G, Park S, Lee D, Kang S, Lee M 2017 J. Korean Phys. Soc. 71 722 doi: 10.3938/jkps.71.722
    [15]
    Seifert M, Gallersdörfer M, Ludwig V, Schuster M, Horn F, Pelzer G, Rieger J, Michel T, Anton G 2018 J. Imaging 4 62 doi: 10.3390/jimaging4050062
    [16]
    Seifert M, Ludwig V, Gallersdorfer M, Hauke C, Hellbach K, Horn F, Pelzer G, Radicke M, Rieger J, Sutter S M, Michel T, Anton G 2018 Phys. Med. Biol. 63 185010 doi: 10.1088/1361-6560/aadafe
    [17]
    Li J, Su X Y, Guo L R 1990 Opt. Eng. 29 1439 doi: 10.1117/12.55746
    [18]
    陈文静, 苏显渝, 曹益平, 向立群 2004 中国激光 31 740 doi: 10.3321/j.issn:0258-7025.2004.06.023

    Chen W J, Su X Y, Cao Y P, Xiang L Q 2004 Chin. J. Las. 31 740 doi: 10.3321/j.issn:0258-7025.2004.06.023
    [19]
    Zhu P, Zhang K, Wang Z, Liu Y, Liu X, Wu Z, McDonald S A, Marone F, Stampanoni M 2010 Proc. Natl. Acad. Sci. U. S. A. 107 13576 doi: 10.1073/pnas.1003198107
    [20]
    Wang Z, Gao K, Ge X, Wu Z, Chen H, Wang S, Zhu P, Yuan Q, Huang W, Zhang K, Wu Z 2013 J. Phys. D: Appl. Phys. 46 494003 doi: 10.1088/0022-3727/46/49/494003
    [21]
    杜杨, 雷耀虎, 刘鑫, 郭金川, 牛憨笨 2013 物理学报 62 06872 doi: 10.7498/aps.62.068702.

    Yang D, Lei Y H, Liu X, Guo J C, Niu H B 2013 Acta Phys. Sin. 62 06872 doi: 10.7498/aps.62.068702.
    [22]
    Momose A, Yashiro W, Takeda Y, Suzuki Y, Hattori T 2006 Jpn. J. Appl. Phys. 45 5254 doi: 10.1143/JJAP.45.5254
  • 加载中

Catalog

    Figures(8)  / Tables(1)

    Article Metrics

    Article views(136) PDF downloads(1) Cited by()
    Proportional views
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return