Volume 70 Issue 10
May. 2021
Turn off MathJax
Article Contents
Xie Shi-Meng, Huang Lin, Wang Xue, Chi Zi-Hui, Tang Yong-Hui, Zheng Zhu, Jiang Hua-Bei. Reflection mode photoacoustic/thermoacoustic dual modality imaging based on hollow concave array[J]. JOURNAL OF MECHANICAL ENGINEERING, 2021, 70(10): 100701. doi: 10.7498/aps.70.20202012
Citation: Xie Shi-Meng, Huang Lin, Wang Xue, Chi Zi-Hui, Tang Yong-Hui, Zheng Zhu, Jiang Hua-Bei. Reflection mode photoacoustic/thermoacoustic dual modality imaging based on hollow concave array[J]. JOURNAL OF MECHANICAL ENGINEERING, 2021, 70(10): 100701. doi: 10.7498/aps.70.20202012

Reflection mode photoacoustic/thermoacoustic dual modality imaging based on hollow concave array

doi: 10.7498/aps.70.20202012
More Information
  • Corresponding author: Huang Lin, E-mail: lhuang@uestc.edu.cn
  • Received Date: 30 Nov 2020
  • Rev Recd Date: 06 Jan 2021
  • Available Online: 27 May 2021
  • Publish Date: 27 May 2021
  • Photoacoustic (PA) and thermoacoustic (TA) imaging can share a set of data acquisition and data processing system, in addition to different excitation sources. In this paper, a reflection mode PA/TA dual modality imaging based on a hollow concave array is proposed. The PA/TA signals are excited through the holes in the hollow array by using optical fiber and dipole antenna, respectively. The excited light, microwave and received ultrasonic signals are coaxial, forming a PA/TA dual modality imaging mode. Through the compensation and calibration of the transducer crystal phase and amplitude of the hollow part of the array, a 3-mm-diameter plastic tube filled with 0.9 wt.% salt water, safflower oil, human arm, back of hand and instep are successfully imaged, separately. These experimental results show that the spatial resolution of the PA/TA dual modality imaging system is 0.33 mm, and this technology has a potential to provide the optical and microwave absorption distribution of tissues at the same time by using the same hollow concave array, which is helpful in accurately detecting tumor, diabetic foot and other diseases, and has a wide range of clinical application prospects.

     

  • loading
  • [1]
    Shi J, Wong T T W, He Y, Li L, Wang L V 2019 Nat. Photonics 13 609 doi: 10.1038/s41566-019-0441-3
    [2]
    Wong T T W, Zhang R, Zhang C, Hsu H C, Maslov K, Wang L, Shi J, Chen R, Shung K K, Zhou Q F, Wang L V 2017 Nat. Commun. 8 1386 doi: 10.1038/s41467-017-01649-3
    [3]
    Wang Y C, Liang G R, Liu F, Chen Q, Xi L 2020 IEEE. Trans. Biomed. Eng. 99 1
    [4]
    Gottschalk S, Degtyaruk O, Mc Larney B, Rebling J, Hutter M A, Deán-Ben X L, Shoham S, Razansky D 2019 Nat. Biomed. Eng. 3 392 doi: 10.1038/s41551-019-0372-9
    [5]
    Merčep E, Herraiz J L, Deán-Ben X L, Razansky D 2019 Ligh-Sci. Appl. 8 1 doi: 10.1038/s41377-018-0109-7
    [6]
    Jiang H B 2015 Photoacoustic Tomography (Boca Raton, FL: CRC Press) pp1−50
    [7]
    Ivankovic I, Merčep, Elena, Schmedt, C G, Deán-Ben X L, Razansky D 2019 Radiology 291 45 doi: 10.1148/radiol.2019181325
    [8]
    Attia ABE, Balasundaram G, Moothanchery M, Dinish US, Bi R, Ntziachristos V, Olivo M 2019 Photoacoustics 16 100144 doi: 10.1016/j.pacs.2019.100144
    [9]
    Kruger RA, Kopecky KK, Aisen AM, Reinecke DR, Kruger GA, Kiser WL Jr 1999 Radiology 211 275 doi: 10.1148/radiology.211.1.r99ap05275
    [10]
    Wang X, Bauer D R, Witte R, Xin H 2012 IEEE. Trans. Biomed. Eng. 59 2782 doi: 10.1109/TBME.2012.2210218
    [11]
    Huang L, Yao L, Liu L, Rong J, Jiang H B 2012 Appl. Phys. Lett. 101 244106 doi: 10.1063/1.4772484
    [12]
    Qin H, Cui Y S, Wu Z J, Chen Q, Xing D 2020 IEEE. Photonics. J. 99 1
    [13]
    Huang L, Li T, Jiang H 2017 Med. Phys. 44 1494 doi: 10.1002/mp.12138
    [14]
    Chi Z H, Zhao Y, Yang J G, Li TT, Jiang H B 2018 IEEE. Trans. Biomed. Eng. 66 1598
    [15]
    Zheng Z, Huang L, Jiang HB 2018 Appl. Phys. Lett. 113 253702 doi: 10.1063/1.5054652
    [16]
    Eckhart AT, Balmer RT, See WA, et al. 2011 IEEE Trans. Biomed. Eng. 58 2238 doi: 10.1109/TBME.2011.2128319
    [17]
    Patch S, Hull D, See W, Hanson G W 2016 IEEE Trans. Ultrason. Ferroelectr. Freq. Control 63 245 doi: 10.1109/TUFFC.2015.2513018
    [18]
    Ku G, Fornage B D, Jin X, Xu M H, Hunt K K, Wang L V 2005 Technol. Cancer Res. T. 4 559 doi: 10.1177/153303460500400509
    [19]
    Pramanik M, Ku G, Li C H, Wang L V 2008 Med. Phys. 35 2218 doi: 10.1118/1.2911157
    [20]
    Ke H, Erpelding T N, Jankovic L, Liu C, Wang L V 2012 J. Biomed. Opt. 15 056010
    [21]
    Merčep E, Deán-Ben X L, Razansky D 2017 IEEE. Trans. Med. Imaging. 36 2129 doi: 10.1109/TMI.2017.2706200
    [22]
    Reinecke D R, Kruger R A, Lam R B, Delrio S P 2010 Proc. SPIE Int. Soc. Opt. Eng. 7564 489
    [23]
    Li M C, Liu C B, Gong X J, Zheng R Q, Bai Y Y, Xing M Y, Du X M, Liu X Y, Zeng J, Lin R Q, Zhou H C, Wang S J, Lu G M, Zhu W, Fang C H, Song L 2018 Biomed. Opt. Express 9 1408 doi: 10.1364/BOE.9.001408
    [24]
    American Laser Institute. American National Standards for the Safe Use of Lasers ANSIZ136.1. Orlando, FL: American Laser Institute, 2014
    [25]
    Huang L, Ge S, Zheng Z, Jiang H B 2018 Med. Phys. 46 851
    [26]
    IEEE standard for safety levels with respect to human exposure to radio frequency electromagnetic fields 3 kHz to 300 GHz, IEEE Standard C95.1; 1999
    [27]
    Hoelen C G A, de Mul F F M 2001 Appl. Opt. 39 5872
    [28]
    Jeon S, Park E Y, Choi W, Managuli R, Kim C 2019 Photoacoustics 15 100136 doi: 10.1016/j.pacs.2019.100136
    [29]
    Zhang Y P, Li E, Zhang J, Yu C Y, Zheng H, Guo G F 2018 Rev. Sci. Instrum. 89 024701 doi: 10.1063/1.4993507
    [30]
    Wang X, Huang L, Chi Z H, Jiang H B. 2021 Phy. Med. Biol. (Under Review)
    [31]
    Choi W, Park E Y, Jeon S, Kim C 2018 Biomed. Eng. Lett. 8 1 doi: 10.1007/s13534-018-0058-3
    [32]
    Ji Z, Ding W Z, Ye F H, Lou C G 2016 Ultrason. Imaging 38 276 doi: 10.1177/0161734615601987
    [33]
    Chi Z H, Liang X, Wang X, Huang L, Jiang H B 2020 IEEE J. Electromagnet. RF Microwaves Med. Biol. 99 1
    [34]
    Yang J G, Zhang G, Wu M, Shang Q Q, Huang L, Jiang H B 2019 J. Biophotonics 12 e201900004
  • 加载中

Catalog

    Figures(7)

    Article Metrics

    Article views(206) PDF downloads(11) Cited by()
    Proportional views
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return